HTR-150/45DXC Nosed Rockwell,Superficial Rockwell hardness tester

HTR-150/45DXC Nosed Rockwell,Superficial Rockwell hardness tester
HTR-150/45DXC Nosed Rockwell,Superficial Rockwell hardness tester
HTR-150/45DXC Nosed Rockwell,Superficial Rockwell hardness tester


Product Introduction:

1) The specially designed indenter is extended horizontally, which can measure the parts that are unable to be measured by the general hardness tester, such as ring and tube, with the minimum test inner diameter of 25mm。

2) Adopting electronic and electric loading, high precision sensor, with unique closed loop control system.

3) Touch screen interface, easy to operate, directly select the hardness scale, the force value is automatically changed in the test parameters.

4) According to the standard hardness block, the three segments of each hardness scale are automatically corrected.

5) The test force can be modified automatically by standard dynamometer.

6) Auto-loading main test force

7) The data processing function is powerful, including: HR, HB, HV and other hardness type conversion, setting up the qualified range, automatic alarm for over-limit, and inputting the information such as tester, sample name, etc.

8) More samples and test information, the measurement data U disk saved in EXCEL format, easy to edit and process.

Technical parameters

Rockwell initial test force

10kgf(98.07N)

Superficial Rockwell initial test force

3.0kgf(29.4N)

Rockwell total test force

60kgf(588N) 100kgf(980N) 150kgf(1471N)

Superficial Rockwell total test force

15kgf(147.1N) 30kgf(249.2N) 45kgf(441.3N)

Rockwell hardness scale

HRA、HRB、HRC、HRD、HRE、HRF、HRG、HRH、HRK、 HRL、HRM、HRR、HRP、HRS、HRV

Superficial Rockwell hardness scale

15N、15T、15W、15X、15Y、30N、30T、30W、30X、30Y、45N、45T 、45W、45X、45Y

Rockwell measurement range

HRA:20-88、HRB:20-100 、HRC:20-70 、HRD:40-77 、HRE:70-100 、HRF:60-100 、HRG:30-94、HRH:80-100、HRK:40-100、HRL:100-120 HRM:85-115、 HRR:114-125

Superficial Rockwell measurement range

HR15N:70-94 HR30N:42-86 HR45N:20-77

HR15T:67-93 HR30T:29-82 HR45T:1-72

Test force dwell time

0-99s

Hardness resolution

0.1HR

Force error

<1.0%

Data output

LCD display

Data storage

The measured values are stored in the U disk in EXCEL format

Conversion scale

Brinell, Vickers

Carried standard

BSEN 6508, ISO 6508, ASTM E18, GB/T230

Maximum allowable specimen height

300mm

Distance from indenter to wall

250mm

size

720×260×840mm

Weight

80kg

Power supply

AC220+5%,50~60Hz



Deixe uma mensagem

Você também pode entrar em contato comigo por e-mail. Meu endereço de e-mail é admin@hssdtest.com

Cita rápida: